Specifications; Fa2000C Control - First Alert FA2000C Installation And Setup Manual

Hide thumbs Also See for FA2000C:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

FA2000C Control

Physical:
12-1/2" W x 14-1/2" H x 3" D (318mm x 368mm x 76mm)
Electrical:
Voltage Input:
Rechargeable Back-Up Battery:
Battery Charging Output:
Bell Output:
Auxiliary Power Output:
Auxiliary Relay Output:
Total Output Power:
Standby Time:
Fusing:
Communication:
Formats Supported:
Line Seize:
TLM Threshold:
Ringer Equivalence:
FCC Registration No. AC398U-68192-Al-E
Maximum Zone Resistance:
Zones 1–4 = 300 ohms excluding EOLR; Zone 5 = 100 ohms excluding EOLR
Built-in Indicators:
Seven LEDs:
Warning Buzzer:
Remote Keypads:
Supports up to four FA260KP fixed word and FA570KP alpha keypads depending on system usage and current
loading. When used as a slave DACT, keypads are optional, but may be used for supplemental DACT status
annunciation. When used as a stand-alone control, one keypad, mounted within 3 feet of the control, with the
wiring run in conduit, must be used.
From built-in transformer supplying 18VAC at 40VA to FA2000C.
Transformer requires nominal 120VAC, 600mA input.
12VDC, 7AH min., 14AH, max. (Gel type).
Charging Voltage: 13.65VDC, minimum to fully charge battery(s).
12VDC, 1.0A output. Selectable for style Y EOLR supervision (using
EOLR20) or no supervision.
12VDC, 350mA max.
Selectable for wet form C output rated at 12VDC, 350mA standby max/1A
alarm max or dry form C output with contacts rated at 30VAC/VDC, 2A max,
resistive loads.
Combined aux power and aux relay power standby currents cannot exceed
350mA. Combined aux power, aux relay power and bell alarm currents
cannot exceed 1A.
(see Table in Final Powerup section)
PTC circuit protectors on battery input and on aux. power, aux. relay, and
bell outputs.
ADEMCO 4+2 Express (DTMF, 10 characters per second)
ADEMCO Contact ID Reporting (DTMF, 10 characters per second)
ADEMCO Low Speed 3+1, 4+1, 4+2 (10 pulses per second)
Radionics/SESCOA 3+1, 4+1, 4+2 (20 pulses per second)
Double Pole
Good line when Tip-Ring voltage exceeds 2V; Bad line when less than 2V
0.7B
AC Power, Comm Fail, Line Fault, Silence Audible, Main Dialer Line Seize, Backup Dialer
Line Seize
Piezo-electric buzzer sounds for Alarm, Trouble and Supervisory conditions. Silenced by
pressing the Silence/Reset button, or by Code + [OFF] on a keypad, if used.
A P P E N D I X

Specifications

B
B-1