FA2000C Installation and Setup Guide
Getting On-Line with a Control Panel
NOTES:
The Installer must be on premises during a
•
download.
•
The control panel must be connected to the existing
telephone line (refer to the SECTION 3: Installing
the Control).
For the initial download to occur, the following
•
fields must be programmed in the control panel:
95 Ring Count and 96 Initialize DL ID and
Acct #.
When establishing a connection between the computer
and the control panel, the following occurs:
Stage
First Communication
1
The computer calls the control panel. (The
phone number for each customer must be
entered into the customer's account file on
the computer.)
2
The control panel answers the phone call at
the pre-programmed ring count (95) and
executes a handshake with the computer.
3
The panel acknowledges the request and
establishes the session without having to
call back.
4
Once the control panel has been successfully
downloaded, the Central Station operator
may disconnect; once disconnected the panel
will again call the Central Station to report
the Program Mode Exit (UL864 required).
Connecting after the First Communication
1
After the initial data exchange with
Compass, the panel (and Compass) hangs
up.
2
Compass goes into a "Waiting For Callback"
mode (regardless of the "Waiting For
Callback" setting) see UL note below.
3
The control panel then calls the Primary
Phone (41) to report the "System-Program
Entry" report. After kissoff the panel then
hangs up.
4
The panel then calls back Compass (94) to
complete the session.
7-2
It is a UL864 requirement that the panel notify
the Central Station whenever an attempt to
enter the program mode is made.
This is why only the initial session allows an
U L
immediate connection to occur. Disabling the
"System-Program Entry" report (54) will allow
sessions without callback to be made, but
violate the UL864 Standard and should not be
done.
Alarms and Trouble responses and reports
are disabled while you are on-line. All central
station reports are delayed until you complete
the session.
On-Line Control Functions
The following functions can be performed while on-line
with a control panel:
•
Bypass a zone
•
Force the system to accept a new program
download
•
Shut down communication (dialer) functions (for
nonpayment of monitoring fees in an owned
system)
•
Shut down all system functions (for nonpayment
for a leased system)
•
Inhibit local keypad programming (prevents
takeover of your accounts)
•
Leave a message for customer
•
Command the system to upload a copy of its
resident program to the office
•
Read: system status, AC power status, list of
bypassed zones, list of zones currently in alarm, list
of zones currently in trouble