User Codes

This system provides 1 Installer Code and 5 Secondary Codes (Users 2-6). These are described below.
User codes are required only if a keypad is installed on the control.
Installer Code
The installer programs the 4-digit Installer Code initially as part of the programming procedure. The Installer Code is
the only code that can allow re-entry into programming mode and also, in normal operation mode, is used to enter the 4-
digit code for the main user (user #2), which allows access to the normal functions of the system (The main user {#2} may
also enter additional users, 3-6).
Adding, Changing, and Deleting Secondary User Codes
In normal operation mode, the Installer Code (and user code #2) may be used to assign up to 5 additional
4-digit user codes. It can also be used to remove Secondary Codes from the system (individually).
To assign (or change) a Secondary user code, enter (via keypad):
Installer Code + [CODE key] + User # (2–6) + desired Secondary Code (4-digits)
The system will emit a single beep when each Secondary Code has been successfully entered.
To delete a Secondary user code, enter (via keypad):
Installer Code + [CODE key] + User # (2–6)
NOTES:
All Installer and Secondary user codes permit access to the system for silencing and resetting alarms.
The Installer Code may assign user codes 2-6.
User 2 may assign user codes 3-6.
The Installer Code may bypass ALL zones while users 2-6 may bypass 24 hour non-fire zones only.
The Installer Code may initiate both the Walk Test and Fire Drill Test.
User 2 may initiate the Fire Drill Test only.
Users 3-6 may NOT initiate any of the test modes.
If a Secondary Code is inadvertently repeated for different users, the lower user number will take priority.
User #
1 Installer
2 Main User
3-6
User Code Function Summary Table
Enter Program
Silence Alm,
Mode
Trbl, Supv
Yes
Yes
No
Yes
No
Yes

System Operation

Add/Change
Bypass
Users
Zones
1-6
All
2-6
24 hour only
No
24 hour only
S E C T I O N
Enter Test
Modes
All
Fire Drill only
None
8
8-1