Alarms - Hitron H4R15MX User Instructions

Color dvr monitor
Table of Contents

Advertisement

4-8. Alarms

ALARM ACKNOWLEDGE :
·
ON : Pressing any key will silence the internal buzzer and turn off the relay only when
the real alarms release.
OFF : Pressing any key cannot silence the internal buzzer and cannot turn off the relay.
4-8-1. Sensor Alarm Setup
Sensor input type : Sensor input type defines the way connectors respond to
·
external input, in terms of whether they are normally open (N.O), normally closed
(N.C), or if they ignore the input (OFF). The default is normally open (N.O).
SCREEN : Set the screen mode when an alarm occurs.
·
There are three possible settings: Full, 2X2 and UNCHANGED.
- Full : When a sensor alarm occurs, the screen displays the camera with the alarm in
the full-screen mode. When sensor alarms occur, the screen sequences cameras with
the alarm in the full-screen mode at the interval of the dwell time.
- 2X2 : When a sensor alarm occurs, the screen switches the 2X2 screen mode.
- UNCHANGED : When a sensor alarm occurs, the screen doesn't change and in the
sequence mode, the monitor keeps the sequence.
DWELL TIME : The dwell time can be set from 1 to 99 seconds. The screen will
·
automatically sequence in a multi-alarm condition with the full-screen format.
The default is 3 seconds.
ALARMS
SENSOR ALARM
VIDEOLOSS ALARM
MOTION ALARM
ALARM ACKNOWLEDGE
SENSOR ALARM SETUP
CAM1
INPUT TYPE
: N.O
CAM2
INPUT TYPE
: N.O
CAM3
INPUT TYPE
: N.O
CAM4
INPUT TYPE
: N.O
SCREEN
: FULL
DWELL
: 03 SEC
HOLD TIME
: 20 SEC
LATCH
: OFF
RELAY
: ON
BUZZER
: ON