2.6 COMBUSTION CHAMBER LINING

Item no. and installation no.
SAP no.
1
10 14 670
2
10 14 678
3
10 14 679
4
10 14 680
5
10 14 675
6
10 14 677
7
10 14 674
8
10 14 676
9
10 14 671
10
10 14 673
10 14 672 (for door height 510)
11
10 14 684 (for door height 570)
Installation of the combustion chamber lining:
The individual chamotte bricks of the
combustion chamber lining must be
i nstalled as numbered, starting with num-
ber (1). The rear baffle plate (10) must be
introduced diagonally into the combustion
chamber until it is above the side walls.
Then the baffle plate must be rotated
horizontally in the free space above the side
bricks and placed in the centre on the side
bricks. In this regard, it is important that the
top side of the deflector plate must be the
rough top side. The front baffle plate (10)
must be inserted in the same manner.
The combustion chamber lining is removed in the reverse sequence.
Important: When removing and installing,
you must ensure that the chamotte does
Quantity
not hit against edges, fall over, etc. The
1
service life of the elements of the com-
bustion chamber lining is reduced through
1
mechanical damage.
1
1
If replacement chamotte bricks are required,
1
they can be requested through the stove fit-
1
ter with the appropriate order numbers.