Troubleshooting - ATEN Master View CS-9134 User Manual

Master view kvm switch
Hide thumbs Also See for Master View CS-9134:
Table of Contents

Advertisement

u
CS-9134:
MVs
Computers
MVs
1
4
7
2
4 - 7
8
3
7 - 10
9
4
10 - 13
10
5
13 - 16
11
6
16 - 19
12

Troubleshooting

Symptom
Possible Cause
Erratic behavior. Unit not receiving enough
power under self-powered
operation.
Pressing the
The connection from the
Hotkeys gets no
selected port to the target
response.
computer has been
broken, or the computer is
turned OFF.
Improper keyboard
reset.
Improper Master View
reset.
Incorrectly keying in the
Port ID.
Mouse is not
Improper mouse reset.
responding.
26
Computers
MVs
Computers
19 - 22
13
37 - 40
22 - 25
14
40 - 43
25 - 28
15
43 - 46
28 - 31
16
46 - 49
31 - 34
17
49 - 52
34 - 37
18
52 - 55
Use the Power Adapter that was supplied with the
unit to provide
Check the Online LED for the selected port. If it is not
lit:
1. Manually press one of the Select switches to
connect to a computer that is powered ON.
2. Check the cables to make sure they are all
properly connected.
1. Reset the keyboard (and mouse) by
simultaneously pressing Buttons 1 and 2 on
the First Stage unit for 3 seconds.
2. Unplug the keyboard connector from the
Console Keyboard Port, then plug it back in.
Turn off all Master View units and wait five seconds
before turning them back on. See Powering Off and
Restarting, p. 12, for details.
After invoking the Hotkey function with the [Numlock
/] combination, be sure to key in the Port ID and press
[Enter] within one second for each key.
1. Reset the mouse (and keyboard) by
simultaneously pressing Buttons 1 and 2 on
the First Stage unit for 3 seconds.
2. Unplug the mouse connector from the
Console Mouse Port, then plug it back in.