Master Connection Section - Netlinx Master Ethernet Ip Address - Listen Mode - AMX NXT-CV10 Operation/Reference Manual

10" modero touch panel
Hide thumbs Also See for NXT-CV10:
Table of Contents

Advertisement

3.
Press the Master IP/URL field to open a Keyboard and enter the Master IP Address (obtained from the
Diagnostics - Networking Address dialog of the NetLinx Studio application).
4.
Click Done to accept the new value and return to the System Settings page.
5.
Do not alter the Master Port Number value (this is the default value used by NetLinx).
6.
Enter a username and password (into their respective fields) if the target Master has been previously
secured.
7.
Press the Back button to open the Protected Setup page.
8.
Press the on-screen Reboot button to both save any changes and restart the panel.

Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode

In this mode, you must add the Modero panel IP Address into the URL List of the Master (using NetLinx
Studio). This mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from
its URL list).
1.
Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP Address
from the IP Settings of the System Settings page.




2.
Toggle the Type field until Ethernet is selected (from the Master Connection section of the System
Settings page).
3.
Press the Mode field (to set the connection Mode) until the choice cycles to the word Listen.
The System Number and Master IP/URL fields are then greyed-out.
4.
Enter a username and password (into their respective fields) if the target Master has been previously
secured.
5.
Select the OnLine Tree tab from the Workspace window.
6.
Select Diagnostics > URL Listing from the Main menu (FIG. 73).
System Address
reflects the value
set in the Device
Addressing tab
Used to obtain an
existing URL
List from Master
Used to set the
URL List
on Master
FIG. 73
URL List dialog
7.
Enter the System and Device number for the specific Master associated with your panel (as seen in the
OnLine Tree tab).
8.
Click Add and enter the IP Address of the Modero touch panel into the Add URL dialog.
9.
Click OK to enter your IP Address and add it to the list.
10.
Click Done once you are finished adding your panel information to the list.
11.
Press the on-screen Reboot button to save any changes and restart the panel.
10" Modero Touch Panels
The DHCP/Static field (in the IP Settings section of the System Settings page) must be set to
DHCP to get Dynamic IP information for the panel.
Press the on-screen Reboot (from the Protected Setup page) to both save any changes and restart
the panel.
After power-up, press the grey Front Setup Access button for 3 seconds to access the Setup page.
Navigate to the Setup > Protected Setup > System Settings page and note the newly obtained
Dynamic IP Address information from the IP Settings section. This information is then entered into
the URL List for the connected NetLinx Master.
Configuring Communication
71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxd-cv10

Table of Contents