AMX NXT-CV10 Operation/Reference Manual page 199

10" modero touch panel
Hide thumbs Also See for NXT-CV10:
Table of Contents

Advertisement

If the panel is already powered, continue with steps 3. The panel MUST be powered
and configured for USB communication before connecting the mini-USB connector to
the panel's Program Port.
2.
Connect the terminal end of the power cable to the 12 VDC power connector on the side/rear of the pane,
and supply power. If using an MVP that is installed onto a docking station, feed power to the docked
panel by connecting the appropriate power supply to the docking station.
3.
After the panel powers-up, access the firmware setup pages by either:
- MVP - Pressing and holding the two lower buttons on both sides of the display for 3 seconds.
- CV7/CV10 - Pressing the grey Front Setup Access button for 3 seconds.
4.
Select Protected Setup > System Settings (located on the lower-left) to open the System Settings page.
5.
Toggle the blue Type field (from the Master Connection section) until the choice cycles to USB.


6.
Press the Back button on the touch panel to return to the Protected Setup page.
7.
Press the on-screen Reboot button to both save any changes and restart the panel. Remember that the
panel's connection type must be set to USB prior to rebooting the panel and prior to inserting the USB
connector.
8.
ONLY AFTER the unit displays the first panel page, THEN insert the mini-USB connector
into the Program Port on the panel.

9.
Complete the USB driver installation process by clicking Yes and then installing the new AMX USB
LAN LINK when told that a new USB device was found. This action accepts the installation of the new
AMX USB driver.
10.
Reboot the panel. Once restarted, the panel is now configured to communicate directly with the PC.
The mini-USB connector MUST be then plugged into an already active panel before
the PC can recognize the connection and assign an appropriate USB driver. This
driver is part of both the NetLinx Studio and TPDesign4 software application
installations.
11.
Launch the Certificate Upload Utility and confirm the utility has detected the new USB connection to the
panel:


10" Modero Touch Panels
The connection remains RED after changing the communication from Ethernet to USB until the
panel is rebooted.
Once the panel restarts, the connection turns a dark green until connected to an active USB cable.
It may take a minute for the panel to detect the new connection and send a signal to the PC
(indicated by a green System Connection icon). If this is your first time installing the USB driver, a
USB driver installation popup window appears on the PC.
Click on the Local Address field's drop-down arrow.
Confirm the new USB entry shows up in the list as: 10.XX.XX.1.
Appendix B - Wireless Technology