Calendar Clock Rules; Time Zone Off Set; Frost/Thermostat Mode Setting - Danfoss TP9000 Installation And User Instructions Manual

Hide thumbs Also See for TP9000:
Table of Contents

Advertisement

Available languages

Available languages

Option 3 - Calendar clock rules
This establishes the rules that the automatic calendar
clock follows to calculate changes between summer
and winter time. Press + until Option 3 is displayed,
use Λ and V to select required setting
Setting 0 Disabled.
Setting 1
Setting 2 European rules. (Factory Setting)
Setting 3 USA rules (2007 onwards)
Setting 4 USA rules (pre-2007)
Option 4 - Time zone off set
This feature allows the time zone to be established
and corrects time display. Press + until Option 4 is
displayed, use Λ and V to select required setting
Setting 0
Setting 1
-12 Hours +14 Hours
Rest of World: use Λ and V keys to select off set from Universal time
(GMT) for the location in which the thermostat is being installed.
Option 10 - Frost/ thermostat mode setting
This feature allows the default frost/thermostat
mode temperature to be set. Press + until Option 10
is displayed, use Λ and V to select required setting.
5-40°C - Factory setting is 5°C, but can be changed to any value
between 5-40°C.
34
Manual: user must change using + to advance and - to
retard displayed time.
UK models: this feature should be left at the factory setting
of 0.
Central European time models: this feature should be left
at the factory setting of +1:00.
TP9000