TP7001 Range
Electronic 7 Day
Programmable Room Thermostat
User Guide
Danfoss Heating

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss TP7001

  • Page 1 TP7001 Range Electronic 7 Day Programmable Room Thermostat User Guide Danfoss Heating...
  • Page 2: Programmable Room Thermostat

    Marketing on 0845 121 7400. Certification Mark Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
  • Page 3 Thank you for buying a Danfoss product Danfoss Heating...
  • Page 4: Table Of Contents

    User Instructions TP7001 Range Electronic Programmable Room Thermostat Index 1.0 User Instructions ..................6 Your programmable room thermostat ........6 Display ....................7 Preset programmes ...............8 Before you start ................8 Display preferences ...............9 Setting the date and time ............9 Accepting the preset programme ........11 Before you change the preset programme .......
  • Page 5: What Is A Programmable Room Thermostat

    Programmable room thermostats need a free fl ow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fi res, televisions, wall or table lamps may prevent the thermostat from working properly. Danfoss Heating...
  • Page 6: User Instructions

    A/B programme operation. The TP7001 can be set by your installer to provide up 2, 4 or 6 time and temperature settings each day. The TP7001 features useful overrides, including a programmable frost setting.
  • Page 7: Display

    Λ Up Arrow: Temperature override up Auto Mode (6 events per day) Auto Mode (4 events per day) Auto Mode (2 events per day) or All Day Mode V Down Arrow: Temperature override down OFF: Thermostat (Off ) Mode + HRS: Extend function Danfoss Heating...
  • Page 8: Preset Programmes

    1.3 Preset Programmes Your TP7001 comes ready programmed with a set of operating times and temperatures which often suit most people. Weekdays (Mon-Fri) Weekend (Sat-Sun) Event Time Temp °C Event Time Temp °C 06:30 07:30 08:30 09:30 11:30 11:30 13:30...
  • Page 9: Display Preferences

    1.6 Setting the Time and Date Setting the correct date and time Your TP7001 incorporates a real time clock with calendar function that automatically changes time in both Spring and Autumn. The time and date is set in the factory for the relevant time zone (GMT, CET or CET+1), and does not normally require adjustment.
  • Page 10 After setting the date press PROG to display the time. The time display will fl ash on and off . Use the + and - buttons to set the correct time (press and hold to change in 10 minute increments). (Fig. 4) TP7001...
  • Page 11: Accepting The Preset Programme

    In 5/2 day mode (Fig. 8) you can enter one set of programmes for weekdays and another set for weekends (see page 14). Fig. 7 Fig. 8 Note: Either weekdays or weekend days are shown in the display. Danfoss Heating...
  • Page 12: Programming In 7-Day Mode

    Use the  or  buttons to alter temperature in 0.5°C (1°F) steps. Fig. 11 Fig. 10 iii) Press NEXT to advance to next Event for that day. iv) Repeat steps i, ii and iii above for the remaining events (Fig. 11). TP7001...
  • Page 13 5. To exit advanced copy mode press the DAY button until the day copied from is selected and press the COPY button. Note: Advanced Copy can only be used if the Advanced Copy Function has been enabled in option 2 in User Advanced Programming (see page 23). Danfoss Heating...
  • Page 14: Programming In 5/2 Day Mode

    COPY button to repeat weekday programme. To return to RUN mode, press and release the PROG button. The display will change to show the current time, set temperature and actual temperature (Fig. 15). Fig. 13 Fig. 14 Fig. 15 TP7001...
  • Page 15: Programming In 24 Hour Mode

    Press and hold the PROG and V buttons for 3 seconds. The display will change to that shown in Fig. 19. This will take you into User Advanced Programming Mode option 1. Use the Λ or V buttons to enable or disable the function (1=enabled, 0=disabled). Fig. 19 Danfoss Heating...
  • Page 16 Press the PROG button, the fi rst preset time and temperature (Event 1 for Programme A) appears in display (Fig. 22). b) Use the + or - buttons to adjust the TIME (press and hold to change in 10 minute increments). Fig. 22 TP7001...
  • Page 17 Repeat steps b, c, and d to programme the remaining events. Running the programme Press the PROG button to return to previous RUN mode. The heating will now follow the times and temperatures programmed (Fig. 26). Fig. 23 Fig. 24 Fig. 25 Fig. 26 Danfoss Heating...
  • Page 18: Advanced Functions

    2.2 Thermostat mode The TP7001 can be converted to control at a constant user selected temperature, instead of following the set programme. Press and hold the  and  buttons together until the display changes to the colon fl ashing and default frost temperature (5°C).
  • Page 19: Holiday Mode

    2.3 Holiday Mode The TP7001 can control at a constant low temperature while you are away on holiday, returning to your programmed settings at a specifi ed date. Press and hold the DAY button for at least 3 seconds (the display will show a suitcase and a date with the year fl ashing - Fig 27).
  • Page 20: User Overrides

    2.4 User Overrides Sometimes you may need to change the way you use your heating temporarily, e.g. due to unusually cold or warm weather. The TP7001 has several user overrides, which can be selected without aff ecting the set programmes. When user overrides are active, the hand symbol will be additionally shown fl ashing to indicate a manual change is active.
  • Page 21: Extend Set Temperature By 1, 2 Or 3 Hours

    To change from Summer to Winter (turn clocks back) With clock display showing, press and hold - button until time moves back. To change from Winter to Summer (move clocks forward) With clock display showing, press and hold + button until time moves forward. Danfoss Heating...
  • Page 22: Delay Start Feature

    User Advanced Programming, option 10, (page 25). To locally override this feature press and hold both Λ and V together. The remote override function will also allow for exit from Holiday Mode. TP7001...
  • Page 23: User Advanced Programming

    Functionality. Press + until Option 2 is selected, use Λ or V to select required setting. 0 = Copy function copies yesterday’s events into today (Factory Setting) 1 = Copy function can copy any day into any other Danfoss Heating...
  • Page 24 Press + until Option 5 is displayed, use Λ or V to select required setting. 0 = Backlight Disabled 1 = Backlight On for 6 seconds after a button press (Factory default) 2 = Backlight Always On TP7001...
  • Page 25 This setting must be used together with Option 12 to match the delayed setting to the building in which it is installed. Danfoss Heating...
  • Page 26 75 mins, radiator system, light weight well insulated building. 60 mins, radiator system, light weight medium insulation. (Factory Setting) 45 mins, radiator system, medium weight poorly insulation. 30 mins, radiator system, heavy weight building, well insulated. 15 mins, radiator system, heavy weight building, poorly insulated. TP7001...
  • Page 27: Overview Of Installer Selectable Features

    3.1.3 Keyboard lock This allows the installer to limit or lock the keyboard to prevent unauthorised changes to programme values and limits overrides. Note: Partial keyboard - Padlock symbol will fl ash Full keyboard - Steady Padlock symbol Danfoss Heating...
  • Page 28: In Case Of Low Battery

    SEr and the service due date. The visual and audible warnings will remain until a button is pressed to cancel them. If cancelled the alarm will recommence the following day at noon. The alarm symbol will fl ash as a constant reminder. TP7001...
  • Page 29: Resetting The Unit

    +HRS overrides that may be active. If the time and temperature for the next event is shown fl ashing, then this is showing an approximate time as an Optimised Start or Delayed Start is active, or a timed override is currently being run. Danfoss Heating...
  • Page 30: Settings Reference

    Installer Set Value Enable or Disable A/B Programming Enable/Disable Advanced Copy Calendar Clock Rules Time Zone Off set LCD Backlight Frost/Thermostat Mode Setting Start-up Method Optimum Start Control / Delayed Start Maximum Activation Time Setting Optimum Start Control/Delayed Start Event Setting TP7001...
  • Page 31 +HRS Enable/Disable Thermostat calibration bias Defi ne remote sensor 1 type (Connection b) Defi ne remote sensor 2 type (Connection C) Defi ne remote sensor 3 type (Connection d) Set limit sensor set-point Confi gure digital input switch Danfoss Heating...
  • Page 32 Danfoss Ltd. Ampthill Road Bedford MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: ukheating@danfoss.com Website: www.heating.danfoss.co.uk Part No. 37033v01 11/11...