WALL SHEATHING
FACTORY-INSTALLED
NON-COMBUSTIBLE
FINISHING MATERIAL
OVERLAP FIT = 0-1 IN. THICK
INSIDE FIT = 0-4 IN. THICK
TEMPLATE BRACKET
Figure 10.3 Finishing Materials
Decorative facing material thickness is measured from
the face of the factory-installed non-combustible board.
See Figure 10.2 and Figure 10.3.
The fronts for this appliance are compatible with non-
combustible materials up to four inches thick. See Figure
10.2 and Figure 10.3.
Refer to Section 1.E and 1.F of this manual for defi nitions
and qualifi cations of non-combustible and combustible
materials.
Specifi c requirements for each method if installation are
described in this section.
Installation of fi nishing materials can be accomplished by
either the "overlap" or "inside-fi t" method, depending on
what type of decorative front is to be installed. Overlap
fi t decorative fronts include the Four Square and Illusion.
The Clean Face Trim Front (CFT) is an inside fi t decorative
front.
Heatilator • CRAVE4836, CRAVE4836ST, CRAVE6048, CRAVE6048ST Installation Manual • 2301-970 Rev. E • 8/14
1/2 IN. THICK
1/2 IN.
NON-COMBUSTIBLE
BOARD
NON-COMBUSTIBLE
FINISHING MATERIAL
OVERLAP FIT = 0-1 IN. THICK
INSIDE FIT = 0-4 IN. THICK
TEMPLATE BRACKET