CRAVE4836, CRAVE4836ST
CRAVE6048, CRAVE6048ST
V
+ V
Minimum
1
2
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1219 mm
5 ft.
1524 mm
V
+ V
+ H
+ H
= 63 ft. (19.2 m) Maximum
1
2
1
2
H
+ H
= 23 ft. (7.1 m) Maximum
1
2
Figure 4.13
Heatilator • CRAVE4836, CRAVE4836ST, CRAVE6048, CRAVE6048ST Installation Manual • 2301-970 Rev. E • 8/14
24
Top Vent - Vertical Termination
Venting with 3 elbows
H
+ H
Maximum
1
2
4 ft.
1219 mm
9 ft.
2743 mm
12 ft.
3658 mm
15 ft.
4572 mm
V
2
H
2
HORIZONTALLY
WARNING! Risk of Fire!
DO NOT attach elbow directly to the appliance.
• This appliance requires a minimum of 24 inches of vertical
venting before attaching any elbow to the appliance.
Note: Use DVP Series
components only.
H
1
INSTALLED
V
1