4. Screen elements

Battery

1
Full battery - indicates battery is
between 100% and 70% of usable
battery capacity
Partial battery - indicates battery is
between 70% and 30% of usable
battery capacity
Low battery - indicates battery is
between 30% and 10% of usable
battery capacity
Critically low battery - battery is
between 10% and 1% of usable
battery capacity. When final
segment flashes, batteries have low
power. The thermometer will take a
proper measurement but batteries
must be replaced soon. If
rechargeable batteries are in use,
batteries should be recharged.
Empty battery - battery has 1% or
less of usable battery capacity.
When battery outline flashes, the
thermometer will not operate.
Replace the batteries. If
rechargeable batteries are in use,
batteries should be recharged.
See 14.7 Maintenance and
service, Replacing the batteries
Probe cover icon
2
The icon animates in an upward motion to
remove probe cover. The icon animates in
a downward motion to apply a probe cover.
See 9. Using the PRO 6000
Timer icon
3
The PRO 6000 includes a 60 second timer
that features an audible notification and
visual indicator at 0, 15, 30, 45, and 60
seconds. The first quadrant begins flashing
when timer starts and becomes solid at 15
seconds. This repeats for each 15 second
interval. The timer turns off automatically 5
seconds after 60 seconds is completed.
See 10.3 Controls, Manual timer
8
1
2
Alert icon
4
Icon that appears with error message.
See 12. Errors and notifications
Memory indicator
5
Indicates the reading shown on the display
is the reading in memory.
See 10.1 Controls, Memory
C/F scale
6
Indicates default temperature scale. Either
°C or °F will display, depending on setting.
See 10.2 Controls, C/F Celsius/Fahrenheit
Security unlock icon and
7
countdown time
(Requires charging station or compatible
Welch Allyn Vital Signs device, sold
separately.) If the security function is
enabled, it requires the thermometer be
returned to the charging station within a
pre-selected time interval. Countdown time
indicates the amount of time remaining
until the thermometer will be locked if not
returned to the charging station. See 11.2
Settings, Advanced functions
Security lock icon
8
(Requires charging station or compatible
Welch Allyn Vital Signs device, sold
separately.) Indicates the thermometer
is locked. Return the thermometer to the
charging station to reset the countdown
and resume normal operation. See 11.2
Settings, Advanced functions
7
6
5
3
4