SiMT041311E
When you clean the filters, open the front panel and remove the dust box.
Air filter (white)
If the AUTO CLEANING FILTER operation is set to "On", basically
no care is required.
When you are aware of dirt, such as when oil or nicotine is
attached to the air filter or when the AUTO CLEANING FILTER
operation is set to "Off", clean the filter.
When?
When you find dirt or dust.
How?
• Use a vacuum cleaner to remove dust.
• If you cannot remove dirt or dust completely, soak the filter in
lukewarm water with neutral liquid detergent and clean with a
sponge.
• After washing the filter, drain it.
• Smooth the filter by hand and dry it well in the shade.
Attention
• Do not disassemble the air filter.
1.
Pull down the filter holding frame
(yellow).
• The tabs of the filter holding frame (yellow) are provided one
on each side.
Filter holding frame (yellow)
2.
Pull out the air filter.
1) Hold the PULL tab on the display unit (black), direct the
unit upward.
2) Raise the grips of the air filter (blue) upward to the front.
3) Pull the grips downward.
Display unit (black)
1)
2)
Installation / Operation Manual
Page 28
PU L L
Pull down
Air filter
3)
PU L L
Grips (blue)
Attaching the air filter
1.
Hold the grips (blue) and insert the
filter along the rail.
• After attaching the air filter, direct the display unit (black)
downward.
Rail
Grips (blue)
2.
Push up the filter holding frame
(yellow) until it clicks.
Filter holding frame (yellow)
If the frame is not securely locked, the front panel may be
damaged.
After cleaning, start the CLEANING FILTER operation to
check that the air filter operates correctly.