SiMT041311E
No.
Menu
9
CONTRAST
< Note >
• This function sets the contrast of the LCD.
24 HOUR
10
FRESH AIR
< Note >
• Even if you stop the air conditioner with the remote controller, it continues ventilation for 24 hours until you change the setting to
"Off".
• The 24 HOUR FRESH AIR SUPPLY VENTILATION starts itself when the circuit breaker has been turned on.
(The OPERATION lamp of the unit is off during the operation. No display is shown on the remote controller.)
• When the 24 HOUR FRESH AIR SUPPLY VENTILATION is solely operated, the streamer discharge cannot be started.
• When the AUTO CLEANING FILTER is set to "On" and the normal operation of the air conditioner stops for 24 hours or longer,
the 24 HOUR FRESH AIR SUPPLY VENTILATION is terminated and the CLEANING FILTER operation starts (and lasts for
about 11 minutes). After the filter has been cleaned, the 24 HOUR FRESH AIR SUPPLY VENTILATION restarts.
RC
11
ADDRESS
< Note >
• This function sets the address when you install 2 indoor units in the same room and do not want to operate them with 1 remote
controller.
When you set one of the indoor units and one of the 2 remote controllers to "2", the set remote controller can send a signal only
to the set indoor unit.
CHILD
12
LOCK
< Note >
• This function prevents children from operating the remote controller by mistake.
Installation / Operation Manual
Setting
• You can set the contrast between 1 and 5.
1 to 5
The default setting is "3".
• The higher the figure, the darker the indicator.
Push APPLY
Starts 24 HOUR FRESH AIR SUPPLY VENTILATION operation.
2sec.
On
Push APPLY
Stops 24 HOUR FRESH AIR SUPPLY VENTILATION operation.
2sec.
Off *
The default setting is "1" for both the indoor unit and remote controller.
< To set the address to "2" >
1. Open the front panel, and turn on the circuit breaker.
Push APPLY
2. Press
.
2sec.
1 *
3. Press
to select "RC ADDRESS" and press
4. Press
to select "2".
5. Press
(green) blinks for about 1 minute. (This is not an error blink.)
6. Press the indoor unit ON/OFF switch while the OPERATION lamp is blinking.
Push APPLY
2sec.
2
Push APPLY
Press
for about 2 seconds to activate the child lock function.
2sec.
On
Push APPLY
Press
for about 2 seconds to cancel the child lock function.
2sec.
Off
is displayed and the buttons except
Description
for 2 seconds and send a signal to the indoor unit. The OPERATION lamp
is disabled.
Operation Manual
Page 28
.
If you cannot set the address while
the OPERATION lamp is blinking,
redo this procedure from the first step.