Optional Accessories; Tools Required For Installation; Fixing The Installation Plate - Samsung AR**HV5D series User's Installation Manual

Table of Contents

Advertisement

Accessories
• T he flare nuts are attached to the end of each pipe of an evaporator or a service port.
Use the nuts when connecting the pipes.
• T he wire assembly cable is optional. If it is not supplied, use the standard cable.
• T he drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe
as seen in the picture below.

Optional accessories

Insulated Assembly Pipe,
Insulated
Ø12.70 mm x 5 m (1)
Assembly Pipe,
Ø6.35 mm x 5 m (1)
Putty 100 g (1)
Pipe Clamps A (3) Pipe Clamps B (3)
3-wire
Power Cable (1)
Assembly Cable (1)

Tools required for installation

General Tools
• Vacuum Pump(Backward flowing prevention)
• Torque Wrench
• Screw Driver
Tools for test operations
• Thermometer

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing
the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
• Right (A)
• Left (B)
• Underside_right (C)
• Rear_right or left (D)
NA_BETTER_A3050_IB&IM_EN_DB68-04388A-00.indd 35
Insulated Assembly Pipe,
Ø15.88 mm x 5 m (1)
✴✴
12
✴✴
✴✴
18
✴✴
2-wire
3-wire
Assembly Cable (1)
• Pipe Cutter
• Reamer
• Spanner
• Drill
• Resistance Meter
 Direction of pipe
A
D
D
C
English-35
PE T3 Foam Tube
Vinyl Tapes (2)
Insulation (1)
M4 x 25 Tapped
Cement Nails (6)
Screws (6)
• Manifold Gauge
• Stud Finder
• Pipe Bender
• Spirit Level
• L Wrench
• Measuring Tape
• Electroscope
B
Drain Hose,
length 2 m (1)
Drain Plug (1)
12/23/2013 10:25:24 PM