Physical Dimensions - Lincoln Electric PRECISION TIG 275 Operator's Manual

Hide thumbs Also See for PRECISION TIG 275:
Table of Contents

Advertisement

®
PRECISION TIG
275
RECOMMENDED INPUT WIRE AND FUSE SIZES
For all Stick, DC TIG, and Balanced AC TIG Welding at
275A/40% Duty Cycle with out Standard Power Factor
Correction Capacitors Based on the 1999 U.S. National
Input
Fuse
Input
Voltage /
(Super
Ampere
phase/
Lag) or
Rating
Frequency
Breaker
Rating on
Size
1
Nameplate
220-230/1/50/60
125
95
380-400/1/50/60
80
55
415/1/50/60
80
50
For Unbalanced AC TIG Welding Above 275 Amps:
255A/40% Duty Cycle, Auto-Balance Penetration with out
Standard Power Factor Correction Capacitors
Based on the 1999 U.S. National Electrical Code
nput
Fuse
Input
I
Voltage /
(Super
Ampere
phase/
Lag) or
Rating
Frequency
Breaker
Size
1
220-230/1/50/60
150
109
380-400/1/50/60
90
63
415/1/50/60
90
58

PHYSICAL DIMENSIONS

Height
Width
31.0 in.
22.0 in.
787 mm
559 mm
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
-20°C to +40°C (-04° to +104°F)
1
ALSO CALLED 'INVERSE TIME" OR "THERMAL/MAGNETIC " CIRCUIT BREAKERS; CIRCUIT BREAKERS WHICH HAVE A DELAY IN
TRIPPING ACTION THAT DECREASES AS THE MAGNITUDE OF CURRENT INCREASES.
TRANSFORMER INSULATION CLASS
IEC 60974-1
IP21S
N80
Electrical Code
Type 75°C
Type 75°C
Copper Wire in
Copper Ground
Conduit AWG
Wire in Conduit
(IEC) Sizes 40°C
AWG (IEC) Sizes
(104°F) Ambient
4 (21.2 mm 2 )
6 (13.3 mm 2 )
8 (8.4mm 2)
8 (8.4mm 2)
8 (8.4mm 2)
8 (8.4mm 2)
Type 75°C
Type 75°C
Copper Wire in
Copper Ground
Conduit AWG
Wire in Conduit
(IEC) Sizes 40°C
AWG (IEC) Sizes
(104°F) Ambient
4 (21.2 mm 2 )
6 (13.3 mm 2 )
8 (8.4 mm 2)
6 (13.3 mm 2)
6 (13.3 mm 2)
8 (8.4 mm 2)
Depth
Weight
26.0 in.
Approx. 397 lbs.
660 mm
180 kgs.
STORAGE TEMPERATURE RANGE
-40°C to +85°C (-40° to +185°F)
180°C (H)
A 2
INSTALLATION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Precision tig 375

Table of Contents