Specifications; Welding Processes; Physical Dimensions - Lincoln Electric POWER MIG 211i Operator's Manual

Table of Contents

Advertisement

POWER MIG 211i
®
DESIGN

SPECIFICATIONS

POWER SOURCES - INPUT VOLTAGE AND CURRENT
DUTY CYCLE
INPUT VOLTAGE INPUT AMPERES
(OUTPUT)
30%
230
( 5A / 22. V)
60%
120
(95A /
V)
POWER SOURCES -
RECOMMENDED INPUT WIRE AND FUSE SIZES
VOLTAGE/
INPUT
PHASE
AMPERES
(SUPER LAG)
FREQUENCY
EFFECTIVE
OR BREAKER
230/1/60
15A
120/1/60
15A
Also called 'inverse time' or 'thermal/magnetic' circuit breakers;
2
circuit breakers that have a delay in tripping action that decreases
as the magnitude of current increases.

PHYSICAL DIMENSIONS

MODEL
HEIGHT
K
15.10IN
(383MM)
(276MM)
1 Cord and Fuse Sizes based upon the U.S. National Electric Code and maximum output
IDLE AMPS
MAX
22.5A
. A
20A
. A
FUSE
TYPE 75C COPPER WIRE IN
CONDUIT AWG (IEC) SIZES
40C (104°F) AMBIENT
SIZE
2
40
12
20
12
WIDTH
DEPTH
WEIGHT
10.90IN
21.49IN
1 LBS
(546MM)

WELDING PROCESSES

PROCESS
ELECTRODE DIAMETER RANGE
GMAW
FCAW
ENGINE DRIVEN GENERATOR
The machine is designed to operate on engine driven generators as
1
long as the auxiliary can supply adequate voltage, frequency and
power as indicated in the "Technical Speci cation" Installation
Section of this manual. The auxiliary supply of the generator must
also meet the following conditions:
Frequency: 60 Hz
RMS voltage of the AC waveform: 90-250 V; Out of this range will
trigger undervoltage and overvoltage protections.
Generator Minimum 3 kW (120VAC) 6kW (230VAC)
It is important to check these conditions because many engine driven
generators produce high voltage spikes. Operation of this machine
with engine driven generators not conforming to these conditions is
not recommend and may damage the machine and is also NOT
covered by warranty.
6 KG
9
OUTPUT RANGE
(AMPERES)
.025-.035"
20-211
(0.6-1.0MM)
.030-.045"
20-211
(0.8-1.2MM)
DESIGN
WIRE FEED
SPEED RANGE
50-500 IPM
50-500 IPM

Advertisement

Table of Contents
loading

Table of Contents