Section 6: Finishing Around The Fireplace - Montigo PL42DF Installation & Maintenance Manual

Pl series
Hide thumbs Also See for PL42DF:
Table of Contents

Advertisement

PL42DF* Indoor Gas Fireplace

Section 6: Finishing Around the Fireplace

Non-combustible mantels and mouldings may be safely installed
over the top and on the front of the fireplace provided that they do
not project beyond shaded area shown in Figure 22.
Fireplace Facing
When sizing the finish material for your fireplace, it is important
to remember the following: THE OPENING MUST NOT BE
OBSTRUCTED IN ANY WAY - to do so restricts the air supply for
the control compartments and heat exchanger it also prevents
access for servicing controls.
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must
not extend past the fireplace opening at all, because it will interfere
with the access to retainers for removal of glass door.
Horizontal Run
in.
Figure 22. Combustible mantels and facings.
(
)
WARNING!
When covering the upper metal portion of the fireplace, up to 4"
(as shown, Fig.22) with a non-combustible material Please Note:
The decorative facing materials may be subject to temperatures
in excess of 250° F. This should be considered when selecting
facing materials.
CAUTION
We recommend careful consideration be given to the effects of elevated mantel
temperatures which may be in excess of product design, for example: candles, plastic
or pictures. This can cause melting, deformation, discoloration or premature failure of
T.V. radio, and other electronic components.
NOTICE
Do not use ammonia based or abrasive cleaners on the glass, they will permanently
etch the surface. Use an approved gas fireplace glass cleaner such as Kel-Kem or
White off.
Page 22
Installation
Combustible construction
allowed in shaded area
Combustible facing material
Combustible header
Non-combustible header
Top of fireplace
Non-combustible facing
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models
of fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
Side wall clearances are 3". Combustible surrounds may be installed
with 3" clearance to the side of the fireplace as shown in Figure 22a.
4"Non-Combustible
Facing Material
Drywall/Sheetrock
Non-combustible Header
WARNING
Do not place any materials or objects on top of the
valve blind. Doing so could result in failure of door
relief system or heat dissipation.
Figure 22a. Combustible surrounds.
CAUTION
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
4"
3"
XG0217 - 160215.1