Lsu Error: #04-001. Please Turn Off Then On; Lsu Error: #04-002. Please Turn Off Then On; Lsu Error: #04-008. Please Turn Off Then On - Samsung CLX-6220 Troubleshooting Manual

Hide thumbs Also See for CLX-6220:
Table of Contents

Advertisement

Code
04-001
04-002
04-008
Symptom
Laser beam detect signal has not occurred or is irregular.
LSU motor does not operate.
Possible Cause
1. Harness is defective, Connector is not connected properly.
2. LSU is defective.
3. Main Board is defective.
Troubleshooting method
1. Check the LSU connector on Main PBA. Reconnect it. If necessary, replace it.
2. If the problem persists, replace the LSU or Main PBA.
Service Manual
Alignment & Troubleshooting
Error message

LSU error: #04-001. Please turn off then on.

LSU error: #04-002. Please turn off then on.

LSU error: #04-008. Please turn off then on.

CN10/11
CN10/11
LSU LD, Hsync
LSU LD, Hsync
Connector
Connector
4-45
CN15
CN15
LSU Motor
LSU Motor
Connector
Connector
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clx-6250

Table of Contents