2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit
SAP-KRV243GJH
Type
Power Source
Voltage rating
Performance
Capacity
Air circulation (Hi)
Moisture removal (High)
Electrical Rating
Available voltage range
Running amperes
Power input
Features
Controls/Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Air filter
Operation sound
Refrigerant tubing connections
Refrigerant
tube diameter
Refrigerant
Refrigerant tube kit
Dimensions & Weight
Unit dimensions
Net Weight
kW
L/S
Liters/h
V
A
W
Horizontal
Vertical
Hi/Lo
dB-A
Narrow tube
mm(in.)
Wide tube
mm(in.)
Height
mm
Width
mm
Depth
mm
Kg
Wall mounted type indoor unit
Cooling
0.6-7.9
305
4.0
Cooling
8.5
1950
Microprocessor / I.C. thermostat
Wireless remote control unit
ON/OFF 24 hours & Daily program, 1- hour OFF
Washable, Anti-Mold
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2
240V~50Hz
240V
Heating
0.8-9.6
325
-
Heating
216 ~ 264
12.7
2920
3 and Auto
Manual
Auto
47/38
Flare type
6.35(1/4)
12.7(1/2)
R410A
Optional
330
1,140
228
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap-kcrv243gjSap-kcrv303gjhSap-kcrv303gj