Heat & Glo Infinity Owner's Manual page 30

Hide thumbs Also See for Infinity:
Table of Contents

Advertisement

PLUG-IN
3V TRANSFORMER
LOW VOLTAGE
SEE NOTE 1
HIGH
TEMP
IGNITION
SWITCH
MODULE
(3V)
VALVE
GROUND
NEUTRAL
REMOVE THESE CONNECTORS
TO WIRE SWITCHES
OPTIONAL
WALL
SWITCH
OPTIONAL
REMOTE
CONTROL
REMOVE THESE CONNECTORS
TO WIRE REMOTE
BLACK WIRE CAN BE
PLUGGED INTO ANY OF #1 - #5
LOCATIONS ON THE HOT SIDE
Figure 10.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram
30
BLK
LOW VOLTAGE
SEE NOTE 1
REMOTE
CONTROL HOT
YLW
YLW
BLK
YLW
BLK
Heat & Glo • Infi nity • 2003-900 Rev. N • 2/10
FAN
WHT
RELAY
BRN
BRN
WHT
BLK
TRANSFORMER
3 VAC
WHITE WIRE
CAN BE
PLUGGED INTO
ANY OF #1 - #5
LOCATIONS
ON THE
NEUTRAL SIDE
PLUG IN
*Note: Appliance will not operate unless properly grounded.
IGNITION
MODULE
3 VAC
ORG
GROUND TO
FIREPLACE
CHASSIS
BRN
HIGH LIMIT
SWITCH
BRN
INTERMITTENT
PILOT IGNITOR
VALVE

Advertisement