Electrical Information; Recommendation For Wire; Optional Accessories; Connecting To The Appliance - Heat & Glo Infinity Owner's Manual

Hide thumbs Also See for Infinity:
Table of Contents

Advertisement

10
10

Electrical Information

A. Recommendation for Wire
This appliance requires that continuous 110-120 VAC be
wired to the factory installed junction box. Maintain cor-
rect polarity when wiring the junction box. See wiring dia-
gram for details.
B. Optional Accessories
Optional remote control kits can be used with this product.
The remote control receiver should be placed on the fl oor
of the valve area in a convenient location keeping in mind
that service will be performed through the inner access
panel. For the WSK-MLT (Intellifi re) kit follow Figure 10.3.
A wall switch is provided and is recommended even if a
remote control is installed. The wall switch is 110-120VAC
and requires appropriate wire be used. A junction box
should be used for the wire connections. See wiring dia-
gram for details.
Note: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
C. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to the WSK-MLT wall control.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety lockout
and may cause explosion.
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
• If using thermostat use one compatible with a millivolt
gas valve system.
• Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
• Use low resistance thermostat wire for wiring from the
WSK-MLT to the WSK-MLT wall control.
• Keep wire lengths short as possible by removing any
excess wire length.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
D. Intellifi re Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 10.1.
This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.
Optional Accessories Requirements
Wiring for optional accessories should be done now to
avoid reconstruction.
Heat & Glo • Infi nity • 2003-900 Rev. N • 2/10
Note: Battery powered remote control receivers are not
approved for use with this product.
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
WARNING
Shock hazard.
• Replace damaged wire with type 105º C rated
wire.
• Wire must have high temperature insulation.
29