SETUp & TESTINg

EQUIpMENT TYpE SElECTION SwITCH (Sw1)

This thermostat has the option of being used in heat
pump or heat/cool systems. Switch SW1 located on the
back of the thermostat's face is used to select this option.
This setting can also be checked in the Installer System
Settings under Equipment Type .
Note: Thermostat reboots within 10 seconds after switch
position is changed .

INSTAllER SETUp MENU

HOw TO ENTER THE INSTAllER SETUp MENU TO CHANgE SYSTEM SETTINgS:
press [MODE] to set system to OFF .
press [MENU] to enter main menu .
press and hold [SETUp] for seven seconds, [INSTAll
SETUp] appears .
press [INSTAll SETUp] to enter installer setup menu .
SETTING
SETTING
DESCRIPTION
NUMBER
SETTING
OPTIONS
8
Sw1
HC
HEAT/COOL
HP
HEAT PUMP
HC
HP
press [NEXT] or [bACK] to page through the settings .
press
or
to adjust the setting.
press [DONE] to save and exit, or [CANCEl] to exit
without saving.
The thermostat will discard changes and exit if nothing
is pressed within 60 seconds.
To reset the installer settings to the default, reset the
thermostat by pressing the [RESET] button inside the
battery cover.
SETUp & TESTINg

INSTAllER SYSTEM SETTINgS TAblE

The following table is the list of the settings and their details. Default settings are shown in bold . Some settings are
only available to thermostats set to heat pump or humidistat mode.
System setting
Description
00. NETWORK ADDRESS
Network communication address.
01. NUMBER OF NODES
Total number of thermostats on the network .
02. BAUD RATE
Communication baud rate.
03. CONTROLLER TYPE
Sets controller to Thermostat or Humidistat .
04. EQUIPMENT TYPE
Equipment type is set by SW1 .
05. CONTROL SETUP
Used to lockout heating or cooling outputs
(only available in Heat/Cool mode).
06. AUTO CHANGEOVER
Enable or disable Auto changeover mode.
07. NUMBER OF STAGES
Number of stages of equipment.
08. AUX HEAT STAGES
Number of stages of auxiliary heat equipment.
09. Heat/Cool: FAN
Heat/Cool: Determines if the thermostat or
CONTROL IN HEATING
equipment controls the fan in heating .
Heat Pump: AUXILIARY
Heat Pump: Auxiliary Equipment type.
EQUIPMENT TYPE
10. Thermostat:
Thermostat: Minimum off time for compressor
COMPRESSOR MIN OFF
protection .
TIME
Humidistat: Minimum on/off time for dehumidifier
10. Humidistat:
protection .
DEHUMIDIFIER MIN
ON/OFF TIME
11. Thermostat: HEATING
Thermostat: Minimum off time for heating.
MIN OFF TIME
Humidistat: Minimum on/off time for humidifier.
11. Humidistat: HUMIDIFIER
MIN ON/OFF TIME
12. EQUIPMENT MIN ON
Minimum on time for heating and cooling .
TIME
13. AUTO CHANGEOVER
Minimum time between heating and cooling calls .
TIME
14. REMOTE SENSOR
Select if remote sensor is attached at T1 and T2 .
15. OUTDOOR SENSOR
Select if outdoor sensor is attached at S1 and S2 .
16. CONTROL SENSOR
Control sensor failure response.
BACKUP
17. FIRST STAGE
1st stage differential .
DIFFERENTIAL
18. SECOND STAGE
2nd stage differential .
DIFFERENTIAL
If utilizing a fossil fuel auxiliary heat system, set to Gas or Oil Furnace. In this setting, the heat pump will lock out before the fossil fuel auxiliary
1
heat comes on; eliminating the need for a dual fuel kit. If utilizing electric auxiliary heat, set to Electric. In this setting, the heat pump and
electric auxiliary heat are allowed to run simultaneously.
factory default setting (bold)
and setting range
1
Address selection of 1 to 64 in steps of 1
64
Selection of 1 to 64 in steps of 1
9600
19200
THERMOSTAT
HUMIDISTAT
HEAT/COOl
HEAT PUMP
HEAT AND COOl
HEAT ONLY
COOL ONLY
DISAblE
ENABLE
SINglE
MULTI
ONE
TWO
gAS/OIl HEAT (equipment controls fan)
ELECTRIC HEAT (thermostat controls fan)
1
5 MINUTES
1 to 5 MINUTES
2 MINUTES
1 to 5 MINUTES
2 MINUTES
1 to 5 MINUTES
4 MINUTES
1 to 5 MINUTES
NO
YES
NO
YES
STOP CONTROL (enter Error Mode)
USE bUIlT-IN
1°f (0.5°C)
1°F to 9°F (0.5°C to 4.5°C)
1°f (0.5°C)
1°F to 9°F (0.5°C to 4.5°C)
9