INSTALLING
Continued
101920

INSTALLATION CLEARANCES

Maintain the minimum clearances. If you can, pro-
vide greater clearances from floor, ceiling, and
adjoining wall.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Wall and Ceiling Clearances (see Figure 7)
A. Clearances from the side of the fireplace opening to any combustible wall
should not be less than 16 inches.
B. Clearances from the top of the fireplace opening to the ceiling should not be
less than 42 inches.
Note:
Clearances are
the same if
using optional
cabinet mantel
or built-in
installation.
16"
Figure 7 - Minimum Clearance to Wall and Ceiling

CONVENTIONAL FIREPLACE INSTALLATION

Conventional installation of this fireplace involves installing fireplace along with the
cabinet mantel with hearth base accessories against a wall in your home. Follow the
instructions below to install the fireplace in this manner.
For conventional installation, it is recommended
you use the cabinet mantel or hearth base specified
in this manual. Surface clearances may not be
sufficient with other cabinet mantels and hearth
bases. This may create a fire hazard. See Accesso-
ries, page 31 for correct cabinet mantel and hearth
base.
The instructions below show installation using the cabinet mantel and hearth
Note:
base accessories. The hearth base accessory is optional for this installation. You can
install fireplace and cabinet mantel directly on the floor.
1. Assemble cabinet mantel and hearth base. Assembly instructions are included
with each accessory.
WARNING
WARNING ICON
G 001
42"
WARNING
WARNING ICON
G 001
MINIMUM CLEARANCE
Side Wall - 16 "
Ceiling - 42"
Floor - 0"
Continued
11