INSTALLING
Continued
101920
Approved
Flexible
Gas Line
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer.
See Accessories, page 31.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane gas, not provided)
1. Remove fireplace screen. Remove two screws that hold fireplace screen in place
for shipping. These screws are located near top of screen. Discard screws. Lift
fireplace screen up and pull out to remove.
2. Remove access door from rear or side of fireplace. See Product Identification,
page 4, for access door locations.
3. Remove screws that attach log base assembly to fireplace (see Figure 17).
Carefully lift up log base assembly and remove from fireplace (see Figure 17).
Do not pick up log base assembly by burners. This
could damage burners. Only handle base by grates.
Figure 17 - Removing Log Base Assembly From Fireplace
A.G.A. Design-Certified Manual Shutoff Valve
With 1/8" NPT Tap*
3" Minimum
Figure 16 - Gas Connection
CAUTION
WARNING ICON
G 001
From Gas Meter
(5" W.C. to 10.5" W.C.
Pressure)
Sediment
Trap
Tee Joint
Pipe Nipple
Cap
Continued