UNVENTED (VENT-FREE) FIREBOX
INSTALLATION
NOTICE: A qualified service per-
son must install firebox. Follow
all local codes.
WARNING: Never install the
firebox
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the firebox
• in high traffic areas
• in windy or drafty areas
CAUTION: Log heaters in-
stalled in this firebox create warm
air currents. These currents move
heat to wall surfaces next to fire-
box. Installing firebox next to vi-
nyl or cloth wall coverings or
operating firebox where impuri-
ties (such as tobacco smoke, aro-
matic candles, cleaning fluids,
oil or kerosene lamps, etc.) in the
air exist, may discolor walls.
IMPORTANT: Vent-free gas log heaters
add moisture to the air. Although this is
beneficial, installing firebox in rooms with-
out enough ventilation air may cause mil-
dew to form from too much moisture. See
Air for Combustion and Ventilation, pages 5
through 7.
IMPORTANT: Make sure the firebox is
level. If firebox is not level, log set will not
work properly.
Note: Your Comfort Glow firebox is de-
signed to be used in zero clearance installa-
tions. Wall or framing material can be placed
against any exterior surface on the rear,
sides or top of your firebox, except where
stand-off spacers are integrally attached. If
stand-off spacers are attached to your fire-
box, these spacers can be placed directly
against wall or framing materials.
Use dimensions shown for rough openings
to create the easiest installation (see Built-In
Firebox Installation, page 9).
INSTALLATION
CLEARANCES
WARNING: Maintain the mini-
mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.
Carefully follow the instructions below. This
will ensure safe installation.
Minimum Wall and Ceiling
Clearances (see Figure 6)
A. Clearances from the side of the firebox
opening to any combustible wall should
not be less than 16 inches.
B. Clearances from the top of the firebox
opening to the ceiling should not be less
than 42 inches.
16"
to Side Wall
Figure 6 - Minimum Clearance to Wall, Ceiling, and Floor
8
C. When the firebox is installed on car-
peting or other combustible material,
other than wood flooring, the firebox
should be installed on a metal or wood
panel extending the full width and
depth of the enclosure.
D. Clearances from the bottom of firebox
to the floor is 0 inches.
These fireboxes can be installed as free-
standing units against a wall with the ap-
proved, optional cabinet mantels (see Ac-
cessories, page 15) or as a built-in unit. The
clearances are the same for either installa-
tion method.
CAUTION: Do not install the
firebox directly on carpet or vinyl.
42" to Ceiling
16"
to Side Wall
0" to Floor
104769