CLEANING
AND
MAINTENANCE
TROUBLE-
SHOOTING
Note: All troubleshooting
items are listed in order of
operation.
26
Turn off fireplace and let cool before cleaning.
You must keep control areas, burners, and circulating
air passageways of fireplace clean. Inspect these
areas of fireplace before each use. Have fireplace
inspected yearly by a qualified service person. Fire-
place may need more frequent cleaning due to exces-
sive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNERS
• Use a vacuum cleaner or small, soft bristled brush to clean.
LOGS
• If you remove logs for cleaning, refer to Installing Logs, pages 20 and 21, to
properly replace logs.
• Replace log(s) if broken or chipped (dime-sized or larger).
Turn off fireplace and let cool before servicing. Only
a qualified service person should service and repair
fireplace.
Never use a wire, needle, or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
OBSERVED
POSSIBLE
PROBLEM
CAUSE
When ignitor button
1. Ignitor electrode posi-
is pressed, there is no
spark at ODS/pilot
2. Ignitor electrode broken
3. Ignitor electrode not con-
4. Ignitor cable pinched or
5. Piezo ignitor nut is loose
6. Broken ignitor cable
7. Bad piezo ignitor
WARNING
WARNING ICON
G 001
CAUTION
WARNING ICON
G 001
WARNING
WARNING ICON
G 001
CAUTION
WARNING ICON
G 001
tioned wrong
nected to ignitor cable
wet
REMEDY
1. Replace ignitor
2. Replace ignitor
3. Reconnect ignitor cable
4. Free ignitor cable if
pinched by any metal or
tubing. Keep ignitor
cable dry
5. Tighten nut holding
piezo ignitor to base
panel of log set. Nut is
located behind base
panel.
6. Replace ignitor cable
7. Replace piezo ignitor
101920