OPERATING
FIREPLACE
Continued
101920
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B" in the safety information above. If you
don't smell gas, go to the next step.
5. Turn control knob counterclockwise
control knob for five (5) seconds (see Figure 24, above).
Note: If running fireplace for first time, there will be air in gas line. You may
need to press in control knob for 30 seconds or longer. This will allow air to
bleed from the gas system.
6. Continue pressing control knob in. Press and release ignitor button. This will light
pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not stay lit, contact a qualified service person or gas supplier
for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure, page 24.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3 through 6. This fireplace has a safety
interlock system. Wait one (1) minute for system to reset before lighting pilot
again.
• If control knob does not pop out when released, contact a qualified service
person or gas supplier for repairs.
Thermocouple
8. Turn control knob counterclockwise
should light. Set control knob to any heat level between HI and LO.
Do not try to adjust heating levels by using the manual
shutoff valve.
to the PILOT position. Press in
C-clockwise
Ignitor Electrode
Figure 25 - Pilot
to desired heating level. The burners
C-clockwise
CAUTION
WARNING ICON
G 001
Pilot Burner