IMPORTANT
If you want to use an extension cable when operating your
product, only the following cable dimensions should be used:
- 1.0 mm
2
: max length 40m
2
- 1.5 mm
: max length 60m
- 2.5 mm
2
: max length 100m
Minimum rating:
1.00mm
2
size cable, 10 amps 250 volts AC.
YOUR PRODUCT IS SUPPLIED WITH AN ELECTRIC
MAINS CABLE WIRED DIRECTL Y INTO THE PRODUCT .
1. If the supply cord is damaged, it must be replaced
by your local Husqvarna UK Ltd. Approved Service
Centre or similarly qualified persons in order to avoid
a hazard.
2.Flymo Extension Cables are available from your
local Husqvarna UK Ltd. Approved Service Centre.
3.Do not wire an extension cable directly to your product
yourself. Please contact your local Husqvarna UK Ltd.
Approved Service Centre for further information on the
connectors and kits available.
4.Only use extension cables specifically designed for
outdoor use and which conform to one of the following
specifications: Ordinary rubber (60245 IEC 53), Ordinary
PVC (60227 IEC 53) or Ordinary PCP (60245 IEC 57)
CONNECTORS
Our connectors are suitable for use with 2 core cable
only. Under no circumstances should these connectors
be used for earthed products.
All of our connectors and cables are of splashproof con-
struction. They are not waterproof and must not be left
outside permanently nor should they be submerged or im-
mersed in water. Do not let cable lay or trail through pools of
water or splashed with water from hose pipes.
A
1
B
2
D

Assembly Instructions

2
1
2
C
1

Starting and Stopping

Cables
MAINS PLUG REPLACEMENT
• If the plug supplied is cut off it should be destroyed.
There is an electric shock hazard if a cut off plug is in-
serted into a 13 amp socket.
1. No earth required. Our products are double insulated
to EN60335 and under no circumstances should an
earth be connected to any part of the product.
2. Ensure the mains voltage suits your product.
3. IMPORTANT!
The wires in the mains lead are coloured in accordance
with the following code:
BLUE - NEUTRAL
The wire which is coloured BLUE must be connected to
the Terminal which is marked with the letter 'N' or
coloured BLACK. The wire which is coloured BROWN
must be connected to the Terminal which is marked with
the letter 'L' or coloured RED.
4. It is important that the outer sheath is clamped cor-
rectly into the 3-pin plug.
5. If in doubt consult your local Service Repairer or quali-
fied electrician before the machine is used.
6. A 13 Amp fuse must be fitted to the Mains Plug.
7. The normal plug fuse and household fuse only protect
the electrical equipment and are not a safeguard
against electrocution.
If your product is hard wired i.e. non-detachable
mains electric cable, a conversion kit and exten-
sion cable is available from all Husqvarna Outdoor
Products Approved Service Centres which can be
found in your local Yellow Pages.
Shaft Assembly (A)
1. Locate the lower shaft (A1) into the upper shaft
(A2).
2. Grasp firmly and hold steady the lower shaft. Lo-
cate the upper shaft and snap together firmly.
The unit is correctly assembled when the gap be-
tween the upper and lower shaft has been closed.
Safety Guard Assembly (B) & (C)
1. Locate the safety guard (B1) over the cutting
head (B2). Ensure the nylon line is fed through
the hole in the safety guard as illustrated in fig B.
2. Push into location and turn safety guard in the di-
rection illustrated in Fig C, until a click is heard
and the safety guard is securely locked in posi-
tion.
ENSURE THE SAFETY GUARD IS SECURELY
IN PLACE BY ATTEMPTING TO TWIST GUARD.
WARNING
Cutting head continues to rotate after the trimmer has
been switched off.
To start your trimmer
1. Squeeze the safety lock-off lever/switch lever (D).
To stop your trimmer
1. Release the switch lever.
BROWN - LIVE