36

Mantel Requirements

The mantel (combustible or non-combustible) must be a minimum 48.5" above the base of the
fireplace (see Figure 29).
The maximum mantel depth is 12" (measured from the face).
Mantel
(combustible or non-combustible)
Max. 12"
Min. 48.5"
Base of the Fireplace
Travis Industries
Installation
(for qualified installers only)
Combustible mantel columns (legs) that
protrude more than 3/4" from the glass
frame must meet the sidewall clearance
(10.5" from the glass frame). If they protrude
3/4" or less, they must meet the facing
clearance (6" from the glass frame).
Non-combustible mantel columns do not
have a minimum clearance.
4060623
Figure 29