11 Maintenance and troubleshooting
11 Maintenance and troubleshooting
11 Maintenance and troubleshooting
11 Maintenance and troubleshooting
11 Maintenance and troubleshooting

11.1 Routine maintenance

11.1 Routine maintenance
11.1 Routine maintenance
11.1 Routine maintenance
11.1 Routine maintenance
Only Qualified Personnel must carry out the following operations.
Seasonal inspections of the boiler
Seasonal inspections of the boiler
Seasonal inspections of the boiler
Seasonal inspections of the boiler
Seasonal inspections of the boiler
It is advisable to have Qualified Personnel check the appliance at least once a year:
The pressure of the water in the cold plant must be between 0.5 and 1 bar. Check that it does not exceed
1.5 bar when hot;
The control and safety devices (gas valve, flow switches, thermostats, etc.) must operate correctly;
The burner and exchanger must be clean. Use soft brushes or compressed air to prevent the parts from
being damaged. never use chemical products;
The expansion tank must be full;
The gas and water systems must be sound;
The end part of the air-flue duct must be free from obstructions and must not leak;
The electrodes must be free from deposits and correctly positioned;
The gas flow rate and pressure must correspond to the indications in the relative tables;
The circulation pump must spin free.
Cleaning the boiler and burner
Cleaning the boiler and burner
Cleaning the boiler and burner
Cleaning the boiler and burner
Cleaning the boiler and burner
The boiler needs no particular maintenance. Just clean it once a year. Never use chemical products or
steel brushes to clean the casing or the burner.
Particular care must be taken of all retention systems pertaining to the hermetic chamber (seals, cable
clamps, etc.). This will prevent air leaks which, causing a pressure drop in the chamber itself, could activate
the differential pressure switch which would block the boiler.
After all these operations have been carried out, particular care must also be taken to check
and carry out all ignition and operation phases of the thermostats, gas valve and circulation
pump.
Check that there are no gas leaks after these inspections.