Fitting The Flue Assembly - Ferroli Xignal Service Instructions Manual

Wall mounted, room sealed, wall mounted, room sealed, fan assisted, gas combination boiler, fan assisted, gas combination boiler, computerised and synthesized voice
Table of Contents

Advertisement

6.0
6.0

FITTING THE FLUE ASSEMBLY

FITTING THE FLUE ASSEMBLY
6.0
6.0
6.0
FITTING THE FLUE ASSEMBLY
FITTING THE FLUE ASSEMBLY
FITTING THE FLUE ASSEMBLY
With Sufficient Clearance To Insert Assembly From Inside
With Sufficient Clearance To Insert Assembly From Inside
6.1
With Sufficient Clearance To Insert Assembly From Inside
With Sufficient Clearance To Insert Assembly From Inside
With Sufficient Clearance To Insert Assembly From Inside
6.1.1 Push the air duct seal onto the air duct at the cut end.
6.1.2 Insert the flue assembly into the wall.
6.1.3 Make good internal wall face.
6.1.4 Fully insert the flue assembly into the turret spigot. Insert the self tapping screw supplied. Fully tighten.
6.1.5 Secure the turret.
6.1.6 Slide the air duct seal over the joint.
6.1.7 Check the terminal relationship with the wall as shown in fig. 12.
6.1.8 Make good the outside wall face, re-weatherproof.
With insufficient Clearance To Insert Assembly From Inside
With insufficient Clearance To Insert Assembly From Inside
6.2
With insufficient Clearance To Insert Assembly From Inside
With insufficient Clearance To Insert Assembly From Inside
With insufficient Clearance To Insert Assembly From Inside
6.2.1 From outside, push flue duct, then the air duct through the wall.
6.2.2 Push the air duct seal over the air duct.
6.2.3 Fully insert the flue duct into the turret, then the air duct. Slide, back the seal and secure the air duct with the
self tapping screw provided.
6.2.4 Slide the seal over the joint and secure the turret.
6.2.5 Continue as detailed in 6.1.8 above.
7.0
7.0
ELECTRICAL INSTALLATION
ELECTRICAL INSTALLATION
7.0
7.0
7.0
ELECTRICAL INSTALLATION
ELECTRICAL INSTALLATION
ELECTRICAL INSTALLATION
Electrical installation must be carried out by a competent electrician. The appliance is to be connected to a 230 V
~ 50 Hz supply (see fig. 18). The supply fuse rating is 3A. The terminals are accessible after removing the white base
plate (see fig. 18).
7.1
Procedure
Procedure
Procedure
Procedure
Procedure
7.1.1 The supply cable must be no less than 0.75 mm (24x0.2 mm) to BS6500 table 16.
7.1.2 The earth conductor must be cut longer than the live and neutral (fig. 19).
Connect the Supply Cable to the terminal block marked 230 V ~ 50 Hz, L, N, the supply cable is to be connected as follows:
i)
Connect the brown wire to the L (live) terminal).
ii)
The blue wire to the N (neutral) terminal.
iii)
The green/yellow wire to the (earth) terminal.
7.1.3 Secure the cable with the cable clamp. The supply cable can be connected to the mains supply by the use of an unswitched
shuttered socket-outlet in conjunction with the 3A fused 3 pin plug both in accordance with BS 1363. This provides
complete isolation. Alternatively, a fused double pole switch having a contact separation of at least 3 mm, in all poles
and provided just for the boiler and its external controls can be used. A wiring diagram is provided on the appliance,
attached to the rear of the front panel. In addition, there is one in this manual (fig. 25). Attention is drawn to the
requirements of the current I.E.E. Regulation and in Scotland, the electrical provisions of the Building regulations.
Remote sensors
Remote sensors
Remote sensors
Remote sensors
Remote sensors
The XIGNAL CE is supplied with an internal and external sensor to ensure maximum fuel savings.
Room Sensor
Room Sensor
Room Sensor
Room Sensor
Room Sensor
To be in a position within the property normally used for a room thermostat.
Ensure connections complies with the polarity shown in Figure 18 wired to terminals No. 5 and No. 6.
External Sensor
External Sensor
External Sensor
External Sensor
External Sensor
To be wired to terminals No. 7 and No. 8.
Location of sensor see Figure 21 and 22.
1
L
2
N
3
4
1
5
ROOM
2
S.p.A.
SENSOR
6
20
25
15
30
7
8
9
10
20
230 V ~
50Hz
EXTERNAL
SENSOR
Fig. 18
Brown
Screw
Blue
Fig. 19