Special Functions - Panasonic WH-MDF09C3E5 Installation Manual

Hide thumbs Also See for WH-MDF09C3E5:
Table of Contents

Advertisement

Commissioning
Programming

Special functions

Setting special functions
Danger!
During sterilisation, do not re-
move hot water, as this can
lead to burns or overheating .
The sterilisation function set-
tings must be made by an au-
thorised dealer in accordance
with the local laws and guide-
lines .
Display on operator
Step
1
2
HEATER
3
4
TANK
5
SOLAR
6
HEAT
7
HEAT
8
TANK
9
BOOSTER
10
BOOSTER
11
12
13
14
9 – 82
Aquarea air/water heat pump – Installation manual for monobloc and split systems C, D and E series 05 / 2014
HEAT
COOL
TANK
QUIET
HEATER
FORCE
OPERATION
SETTING
TIMER
OFF/ON
CLOCK
Switch the device off using the OFF / ON button before setting special
functions (operation LED does not light up) .
Description
control panel
External room thermostat (YES / NO, Standard: NO)
Setting whether an external room thermostat is connected .
Select the required output of the additional electric heater (3, 6 or 9 kW, Standard: Maximum) .
The output of the additional electric heater can be reduced if higher power is not needed .
This will depend on model selected .
Water antifreeze function (YES / NO, Standard: YES)
Activation or deactivation of the antifreeze function when the device is switched off .
Connection of a hot-water tank (YES / NO, Standard: NO)
Setting whether a hot-water tank is connected . Note: If "Hot-water tank connected" is set to
NO, steps 5 to 14 are skipped .
Solar priority (YES / NO, Standard: NO)
Setting the priority of the solar installation for water heating .
Heating priority (YES / NO, Standard: NO)
Setting the heating as a priority over hot water .
Note: If "Heating priority" is set to YES, steps 7 to 8 are skipped .
Duration of heating period
Setting the duration of heating mode in the heating and water operating mode .
(30 min . to 10 hours, Standard: 3 hours) .
Water heating duration
Setting the duration for water heating in the heating and water heating operating mode
(5 min . to 1 hour 35 min ., Standard: 30 min .) .
Hot water immersion heating function (YES / NO, Standard: YES)
Activation or deactivation of hot water immersion heater .
Note: If the "Hot water immersion heating function" is set to NO, step 10 is skipped .
Switch-on delay of the electric immersion heater for hot water
Setting the delay period before the immersion heater is switched on for the hot-water tank
if the tank temperature is not reached (20 min . to 1 hour 35 min ., Standard: 1 hour) .
Sterilisation (YES / NO, Standard: YES)
Setting for sterilisation of the hot water .
Note: If "Heating priority" is set to YES, steps 12 to 14 are skipped .
Day and time of sterilisation (Standard: Monday 12:00 noon)
Setting the day and time of weekly sterilisation (even when the device is switched off) .
Sterilisation temperature
Setting the temperature to be used for sterilisation (40 to 75 ℃, Standard: 70 ℃) .
Sterilisation duration
Setting of the period required to retain the tank temperature needed for sterilisation
(5 min . to 1 hour, Standard 10 min .) .
TIMER
OUTDOOR
ACTUAL
HEATER
BOOSTER
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF/ON
STATUS
SET
MODE
CHECK
SEARCH
SELECT
QUIET
HEATER
ERROR
CANCEL
RESET
FORCE
SERVICE
SETTING
STATUS
SET
TIMER
MODE
CHECK
SEARCH
OFF/ON
SELECT
QUIET
HEATER
ERROR
CANCEL
CLOCK
RESET
FORCE
PUMPDW