Setting special functions
Danger!
During sterilisation, do not re-
move hot water, as this can
lead to burns or overheating.
The sterilisation function set-
tings must be made by an au-
thorised dealer in accordance
with the local laws and guide-
lines.
Display on operator
Step
1
2
HEATER
3
4
TANK
5
SOLAR
6
HEAT
7
HEAT
8
TANK
9
BOOSTER
10
BOOSTER
11
12
13
14
Aquarea air/water heat pump – Installation manual for compact systems 03 / 2013
TIMER
HEAT
COOL
TANK
QUIET
HEATER
FORCE
OPERATION
SETTING
TIMER
OFF/ON
OFF/ON
SELECT
CANCEL
CLOCK
CLOCK
Switch the device off using the OFF / ON button before setting special
functions (operation LED does not light up).
Description
control panel
External room thermostat (YES / NO, Standard: NO)
Setting whether an external room thermostat is connected.
Select the required output of the additional electric heater (3, 6 or 9 kW, Standard: Maximum).
The output of the additional electric heater can be reduced if higher power is not needed.
This will depend on model selected.
Water antifreeze function (YES / NO, Standard: YES)
Activation or deactivation of the antifreeze function when the device is switched off.
Connection of a hot-water tank (YES / NO, Standard: NO)
Setting whether a hot-water tank is connected. Note: If "Hot-water tank connected" is set to
NO, steps 5 to 14 are skipped.
Solar priority (YES / NO, Standard: NO)
Setting the priority of the solar installation for water heating.
Heating priority (YES / NO, Standard: NO)
Setting the heating as a priority over hot water.
Note: If "Heating priority" is set to YES, steps 7 to 8 are skipped.
Duration of heating period
Setting the duration of heating mode in the heating and water operating mode.
(30 min. to 10 hours, Standard: 3 hours).
Water heating duration
Setting the duration for water heating in the heating and water heating operating mode
(5 min. to 1 hour 35 min., Standard: 30 min.).
Hot water immersion heating function (YES / NO, Standard: YES)
Activation or deactivation of hot water immersion heater.
Note: If the "Hot water immersion heating function" is set to NO, step 10 is skipped.
Switch-on delay of the electric immersion heater for hot water
Setting the delay period before the immersion heater is switched on for the hot-water tank
if the tank temperature is not reached (20 min. to 1 hour 35 min., Standard: 1 hour).
Sterilisation (YES / NO, Standard: YES)
Setting for sterilisation of the hot water.
Note: If "Heating priority" is set to YES, steps 12 to 14 are skipped.
Day and time of sterilisation (Standard: Monday 12:00 noon)
Setting the day and time of weekly sterilisation (even when the device is switched off).
Sterilisation temperature
Sterilisation duration
Setting of the period required to retain the tank temperature needed for sterilisation
(5 min. to 1 hour, Standard 10 min.).
OUTDOOR
ACTUAL
HEATER
BOOSTER
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF/ON
STATUS
SET
MODE
CHECK
SEARCH
QUIET
HEATER
OFF/ON
ERROR
RESET
FORCE
SERVICE
Commissioning