Dometic 541815 Installation Instructions Manual page 13

Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
FIG. 20
FIG. 21
Use Tip Of Pliers To Hold Wire In Place
FIG. 22
While Hand Bending Wire At 90°
FIG. 23
FIG. 24
Trim Ground Wire To Length Of Outer Wires
Strip Jacket To 1"
Hand Bend White
And Black Wires
Outward 90°
Repeat With
Other Wire
5. Hold the clear strain relief cover with the bottom
facing upward. See (FIG. 25).
Load Cable into Strain Relief
FIG. 25
Roll Cable Sheath Into
Integral Strain Relief
Strain
Relief
Fingers
Strain Relief Cover
(Bottom Facing Upward)
6. Lay wire into locator slots, making sure the black
wire is placed into the polarization slot. See
(FIG. 25).
7. Press the cable sheath into the integral strain
relief slot. See (FIG. 25). Trimming of ground
wire and possibly others will be necessary.
Wires must not extend beyond the locators. See
(FIG. 26).
FIG. 26
Hinge
Posts
Strain Relief Cover
8. While holding the strain relief cover, position
the housing's hinge posts into the hinge slots
and press down until both lock into place. See
(FIG. 26).
9. Close the strain relief cover and housing by
hand. Squeeze the top and bottom closed with
tongue and groove pliers. See (FIG. 27). Pliers
must be a minimum of 10" long. Squeeze firmly
on both sides, squarely across the connector
between ribs A and B to ensure wires seat com-
pletely into slots.
13
Wire Locator
Slots
Position Black Wire
Into Locator Slot
Housing Assembly
Hinge
Slots
Wires Trimmed And
Correctly Located
In Locator Stops

Advertisement