Slot Numbering
When the stack comes up following the reboot, the manually-configured slot numbers display as follows:
Slot 1 - Primary
Slot 2 - Secondary
Slot 3 - Idle
Slot 4 - Idle
The stack set slot command can also be used to manually correct duplicate saved slot assignments within
the stack topology. Refer to pages

Reverting to the Dynamic Slot Numbering Model

To clear the boot.slot.cfg files from the stack's /flash directories, use the
modules and then reboot the stack. For example:
-> stack clear slot 1
-> stack clear slot 2
-> stack clear slot 3
-> stack clear slot 4
-> reload all
The commands shown above clear the saved slot information from all modules in an eight-module stacked
configuration and then reboot the stack. Because the system software no longer has preassigned slot infor-
mation to read during the boot process, the stack uses the dynamic slot number assignment method
described on
page
7-21.
page 7-24
Stack Numbering Before Manual Assignment
7-13
through
7-15
OmniSwitch 6250 Hardware Users Guide
Managing OmniSwitch 6250 Stacks
for detailed information.