13. If linkage is free and choke plate fails to open fully
after 2 minutes, check spring tension of bimetallic
assembly. If necessary, replace bimetallic spring
choke bracket assembly.
14. Reinstall air cleaner element and secure cover.

Thermostat Position Reset

D
E
F
D
E
Spring Tab Must be
A
Located in Lever
Slot
Models KT740,
C
KT745
28
A
B
C
F
Models KT725,
B
KT735
High Position of
D
Adjustment
Range
KohlerEngines.com
Low Position of
E
Adjustment
Range
NOTE: Do not remove or loosen thermostat screws.
Position is set at factory.
NOTE: Thermostat temperature must be at room
temperature before testing.
If thermostat is loosened or removed, use following
procedure to reset position.
1. Unplug thermostat wire.
2. Thermostat position should be set to low position of
adjustment range (E).
3. Once thermostat position is set, engine must be
started at idle with thermostat wire disconnected to
test system function.
4. If engine runs correctly, no further adjustment is
needed.
5. If engine speed does not increase to idle speed on
start up, thermostat position must be adjusted by
rotating housing clockwise in 1 mm increments and
retested. Position should not exceed high
adjustment range shown (D).
6. Plug in thermostat wire.

Starting an Engine Equipped with Smart-Choke

NOTE: Do not crank engine continuously for more than
10 seconds at a time. If engine does not start,
allow a 60 second cool down period between
starting attempts. Failure to follow these
guidelines can burn out starter motor.
NOTE: If engine develops sufficient speed to disengage
starter but does not keep running (a false start),
engine rotation must be allowed to come to a
complete stop before attempting to restart
engine. If starter is engaged while flywheel is
rotating, starter pinion and flywheel ring gear
may clash, resulting in damage to starter.
1. Smart-Choke
system will automatically control
choke plate position for starting.
2. Make sure equipment is in neutral.
3. Activate starter switch. Release switch as soon as
engine starts.
If starter does not turn engine over, shut starter off
immediately. Do not make further attempts to start
engine until condition is corrected. Do not jump start
using another battery. See your Kohler authorized
dealer for trouble analysis.
4. For operation, after engine starts, move throttle and
set desired engine operating speed.
This edge of
metallic ground
F
strap must
fall within
adjustment range
32 690 03 Rev. E