Inspecting Burners - Superior MNF24INM Installation And Operation Instructions Manual

Table of Contents

Advertisement

VARIABLE REMOTE MODELS OPERATION
To activate this function, press THERMOSTAT
button until the word SMART appears to the
right of temperature bulb graphic on display.
Use UP/DOWN arrow button to set desired
room temperature. The control system will
cycle the fi replace on or off to maintain se-
lected temperature.
SMART
MAX
Figure 46 - Smart Thermostat Setting
CHILD SAFETY LOCK-OUT
This function lets you deactivate the remote
control buttons. It is active when the lock icon
is lit on the display.
To activate, press MODE button and UP ar-
row button at the same time. To deactivate,
press again.
ON
Figure 47 - Child Safety Lock-Out
REPLACING HAND-HELD REMOTE
CONTROL ONLY
If your remote ever needs to be replaced you
will not need to replace the receiver.
To program receiver with a new hand-held
remote, insert a small pin or paper clip into
hole on receiver face plate marked PRG.
The receiver will beep 3 times to indicate it
is ready to accept a new remote transmitter.
Press the ON/OFF button on your remote
and the receiver will beep 4 times to confi rm
it receives commands from the new remote.
ON REMOTE OFF
Figure 48 - Programing Remote Control
to Receiver
900463-01A
Continued
Check pilot fl ame pattern and burner fl ame
patterns often.
PILOT FLAME PATTERN
Figure 49 shows a correct pilot fl ame pattern.
Figure 50 shows an incorrect pilot fl ame pat-
tern. The incorrect pilot fl ame is not touching
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools,
the appliance will shut down.
If pilot fl ame pattern is incorrect, as shown
in Figure 50
• turn appliance off (see To Turn Off Gas to
• see Troubleshooting, Page 32
PRG
To
Program
Receiver
SuperiorFireplaces.us.com

INSPECTING BURNERS

Appliance, Page 27
Thermocouple
Figure 49 - Correct Pilot Flame Pattern
Pilot Burner
Figure 50 - Incorrect Pilot Flame Pattern
NOTE: The pilot fl ame on natural gas units
will have a slight curve, but fl ame should be
blue and have no yellow or orange color.
Pilot Burner
Thermocouple