Specifi Cations; Wiring Diagram - Superior MNF24INM Installation And Operation Instructions Manual

Table of Contents

Advertisement

MNF24INM
MNF24INV
MNF30INM
MNF30INV
• Rating (Variable): 29,000/40,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
WIRING DIAGRAM (REMOTE READY MODELS)
To Thermopile
WIRING DIAGRAM (VARIABLE CONTROL MODELS)
NOTE: For proper operation of remote control, wires from thermopile to control receiver must
be connected exactly as shown.
900463-01A
SPECIFICATIONS
MNF24IPM
MNF24IPV
MNF30IPM
MNF30IPV
• Rating (Variable): 29,000/40,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 7.9" W.C.
• Inlet Gas Pressure (in. of water):
*For purpose of input adjustment
Black Connectors
White
Red
SuperiorFireplaces.us.com
Max - 14" W.C., Min* - 11" W.C.
To OFF Terminal
on Switch
To AUTO Terminal
on Switch
Receiver
To Thermopile
31