Outdoor Unit (Ras-07Uax-T2, Ras-10Uasx) - Toshiba RAS-13UKPX-T2 Service Manual

Split wall type
Table of Contents

Advertisement

10-4. Outdoor Unit (RAS-07UAX-T2, RAS-10UASX)

No.
Part name
1
Common
procedure
2
Capacitor for
compressor
3
Capacitor for
fan motor
4
Overload relay
Procedures
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove packed valve cover and electric
parts cover.
(2-Screws ∅4 x 10L)
3) Remove the cord clamp (2-Screws ∅4 x 22L)
and disconnect the connecting cable.
4) Remove the upper cabinet (4-Screws ∅4 x 10L)
Pulling out upword.
5) Remove the front cabinet.
(7-Screws ∅4 x 10L)
Pull the front right portion toward you, and
remove it pulling out upward.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw ∅4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the fixing screw.
(1-Screw ∅4 x 10L)
3) Disconnect the lead wire
1) Perform the common procedure 1.
2) Remove the terminal cover of compressor.
3) Remove the overload relay holder and pull up
the overload relay.
4) Disconnect the lead wires.
– 63 –
FILE NO. SVM-02003
Remarks
2-Screws ∅4 x 22L
2-Screws ∅4 x 10L
For compressor
For fan motor
Overload relay

Hide quick links: