Outdoor Unit (Ras-13Uax); Outdoor Unit (Ras-10Uax-T2, Ras-10Uasx) - Toshiba RAS-13UKPX-T2 Service Manual

Split wall type
Table of Contents

Advertisement

4-3. Outdoor Unit (RAS-13UAX)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Overload relay

4-4. Outdoor Unit (RAS-10UAX-T2, RAS-10UASX)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Overload relay
Type
Output (Rated) 1100W, 2poles, 1 phase, 220 – 240V, 50Hz
PH160T2-4L2
Winding resistance (Ω)
(at 20°C)
Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50/60Hz
HF-240-30B
Winding resistance (Ω)
(at 20°C)
DS501155BPQA
AC 500V, 1.5µF
DS371356CPNB
AC 370V, 35µF
LAAO00A
U/T: 9.0A (80°C), OPEN: 135±5°C, CLOSE: 75±11°C
Type
Output (Rated) 800W, 2poles, 1 phase, 220 – 240V, 50Hz
RM5510GNE94
Winding resistance (Ω)
(RAS-10UAX-T2)
(at 20°C)
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
PH102T1-4C
Winding resistance (Ω)
(RAS-10UASX)
(at 20°C)
Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50Hz
HF-240-30B
Winding resistance (Ω)
(at 20°C)
DS501155BPQA
AC 500V, 1.5µF
DS371256CPNB
AC 370V, 25µF
LPAP960B
U/T: 6.1A (80°C), OPEN: 135±5°C, CLOSE: 78±11°C
– 12 –
FILE NO. SVM-02003
Specifications
C-R
2.43
Red-Black
White-Black
245
Specifications
C-R
2.159
C-R
3.88
Red-Black
White-Black
245
C-S
3.78
388
C-S
3.899
C-S
5.06
388