4-5. Outdoor Unit (RAS-10UA-ES2, RAS-10UA-AS2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Type
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
PA108X1T-4FZ1
Winding resistance (Ω)
(at 20°C)
Output (Rated) 20W, 6poles, 1 phase, 220 – 240V, 50Hz
HF-240-20B
Winding resistance (Ω)
(at 20°C)
DS451155BPQC AC 450V, 1.5µF
DS371256CPNB
AC 370V, 25µF
– 14 –
FILE NO. SVM-03001
Specifications
C-R
3.89
Red-Black
White-Black
387.3
C-S
4.51
466.2