Ras-10Ukx / Ras-10Uasx - Toshiba RAS-13UKPX-T2 Service Manual

Split wall type
Table of Contents

Advertisement

5-5. RAS-10UKX / RAS-10UASX

Cooling
0.39m
(Connecting pipe)
∅9.52
O.D.:9.52mm
P
Packed valve
(∅9.52)
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Indoor unit
Evaporator
Cross flow fan
PH102T1-4C
Accumulator
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
exchanger interchanging
pressure P
(MPaG)
0.52
0.65
0.40
– 18 –
FILE NO. SVM-02003
T1
Packed valve
(∅6.35)
Capillary tube
∅1.5x1400S
Refrigerant
R-22 : 0.65 kg.
Mark(
)means check points of Gas Leak.
Fan speed
(indoor)
pipe T1 (°C)
13.0
High
18.0
High
3.0
Low
0.49m
(Connecting pipe)
∅6.35
O.D.:6.35mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15