B. LOCATION AND CLEARANCES
Model
A
B
36" Series 36"
41"
24
42" Series 42"
47" 30
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND DRAPERIES.
1. APPLIANCE LOCATIONS AND SPACE
REQUIREMENTS
Figure 1 illustrates a variety of ways the appliance
may be located in a room. The CALIBER Series may
be installed directly on the floor or raised on a hearth.
These appliances are certified for installation in a bed-
room or a bed/sitting room in the U.S. and Canada
provided that the bedroom or bathroom have a volume
of at least 1500 cubic feet.
Common venting of this gas appliance with other gas
appliances is NOT allowed in multi-family dwellings.
A hearth extension is not required for this appliance.
Figure 1
Appliance Locations
Model
36" Series 50
42" Series 55
12-97
C
1
/
"
2
Left Hand
1
/
"
Side
2
A
B
C
5
5
42
/
" 71
/
"
"
8
8
48
1
5
/
" 77
/
"
"
4
8
Unit Dimensions
2. CLEARANCES
Figure 2 shows all clearances that must be main-
tained around the appliance. See page 9 for ter-
mination cap clearances. See Figures 4 and 15
for vent clearances.
Appliance Clearances to Combustible Materials
4i
Right Hand
Side
Figure 2
28887A