Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
f i r e - p a r t s . c o m
1. APPLIANCE LOCATIONS AND SPACE
REQUIREMENTS
Figure 1 illustrates a variety of ways the appliance may
be located in a room. The Builder's Choice Series may
be installed directly on the floor or on a hearth. These
appliances are certified for installation in a bedroom,
bed/sitting room or in mobile homes in the U.S. and
Canada.
2. CLEARANCES
a.
For the appliance:
Top of standoffs
Floor
Back of appliance
Sides
Front Face to Ceiling
b.
Minimum Venting Clearances (see Figure 2).
1)
2)
3)
33606 Rev D
BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS
C. LOCATION AND CLEARANCES
Horizontal runs off of the back of the
appliance to the wall shield:
0” above the top of the appliance standoffs
1” sides and bottom of the vent
Horizontal runs inside a wall (heat shields
must be installed)
3” air space on top of the vent
1” from sides and bottom of vent
Vertical runs
1” air space around the vent
Dimensions
WARNING!
Note:
for a centered corner installation. Actual requirements
will vary with individual construction.
0”
0”
1/2”
1/2”
30”
Figure 2 - Rear Vented Appliances Venting Clearances
6
Dimensions represent minimum space required