3. Gas Pressure

On the standing pilot Gas Control Valve, a pressure tap is
included on the front face of the Valve. The electronic Valve
includes an 1/8" NPT plugged tap on the top and bottom of the
Valve near the outlet to the main burner. Pressure taps are
immediately upstream of the gas supply connection and acces-
sible for test gauge connection.
Table 2 shows optimum gas pressure information.
Consult your local gas company for assistance in determining
the proper orifice for your altitude or refer to ANSI Z223.1-latest
edition, Appendix F.

4. Gas Conversions

Natural or propane gas conversions necessary to meet the
application need to be made by a qualified technician using
Heatilator specified and approved parts.
In the event your appliance must be converted to use propane,
you must use a CKVP Conversion Kit. To convert to use natur-
al, you must use a CKVN Conversion Kit.
CALIBER 36" and 42"
Inlet gas supply pressure (natural gas)
Optimum manifold pressure (natural gas)
Inlet gas supply pressure (LP gas)
Optimum manifold pressure (LP gas)
Input rate (natural gas)
Input rate (propane gas)
Decorative - Natural Gas Orifice size
Decorative - Propane Gas Orifice Size
Gas Information for Electronic and Standing Pilot Units
12-97
4.5 (min.)-7.0 (max.) in w.c.
3.5 in. w.c.
11.0 (min.)-14.0 (max.) in w.c.
10.5 in. w.c.
30,000 BTU/hr
28,000 BTU/hr
.110 in/ 2.79 mm
.063 in/ 1.60 mm
Table 2