IBM eServer 135 xSeries User Reference Manual page 97

Hide thumbs Also See for eServer 135 xSeries:
Table of Contents

Advertisement

Table 14. Diagnostic error messages
Code
Function
202
System cache
206
Diskette drive
215
CD-ROM
217
Hard disk drive
Result
Aborted
Test setup error: BIOS cannot access VPD information If your server does not
Test setup error: Corrupt DMI BIOS. Information in
BIOS is not as expected
Test setup error: No L2 cache detected on
microprocessor socket id xyz or BIOS setup problem
(where xyz identifies the microprocessor that is
causing the error message)
Test setup error: Unknown hardware problem
associated with microprocessor in socket id xyz.
(where xyz identifies the microprocessor that is
causing the error message)
Failed
Microprocessor in socket ID xyz
(where xyz identifies the microprocessor that is
causing the error message)
Warning
Test setup error: Cache is disabled. Use system setup
to enable before retrying the test
Failed
Internal diskette drive bay
Failed
On system board.
Aborted
The CD-ROM drive is not present.
Failed
BIOS drive # n (where n is the drive bay number)
Text message
Action
have the latest level
BIOS installed, update
the BIOS to the latest
level and run the
diagnostic program
again.
If the problem persists,
call for service.
1. If your server does
not have the latest
level BIOS
installed, update
the BIOS to the
latest level
2. Run the diagnostic
program again.
3. If the problem
remains, replace the
failing processor.
If the problem persists,
call for service.
1. Reseat the
identified
microprocessor.
2. If the problem
remains, replace the
microprocessor.
If the problem persists,
call for service.
Use the Cache Control
choice from the
Advanced Setup menu
to enable the cache.
If the problem persists,
call for service.
Call for service.
Call for service.
Verify that the cables are
properly connected to
the CD-ROM. If the
problem persists, call for
service.
Call for service.
Chapter 6. Solving Problems
85

Advertisement

Table of Contents
loading

Table of Contents