Installation Instructions - Cadet RCP502S Owner's Manual

The hot one garage heater
Hide thumbs Also See for RCP502S:
Table of Contents

Advertisement

Available languages

Available languages

1. WARNING: Risk of fire. Do not use as a
residential or household heater.
2. Do not use outdoors.
3. This heater is not intended for use in bathrooms,
laundry areas, and similar indoor locations.
4. CAUTION:
Do not operate
attached.
The Hot One may sit on a floor surface or be mounted to the wall using the universal stand provided. If mounted on the
wall, maintain 6 inch minimum clearance from the top of the unit to the ceiling. The Hot One is not recommended for
ceiling mount. Recommended for elevations under 7500 feet.
STEP 1
Heater Inspection
Thoroughly inspect your heater for any shipping or handling damage and remove any paper or packaging material around the heater.
Grounding Plug and Receptacle Requirements
STEP 2
This heater is for use with 240 volts. The cord has a 20 amp or 30 amp plug as shown in Figure 1. No adapter is available for these
blade configurations, and none should be used. The Hot One requires a 240 volt grounded receptacle. When properly installed, it
provides a ground connection through the cord to the heater to protect the operator from electric shock. Do not use an extension cord,
power strip or any kind of adapter.
RCP502S - 30 Amp
Plug Configuration
Receptacle Configuration
NEMA #6-30R
STEP 3
Mounting
Floor Standing
1. Loosen knobs on each side of the heater.
2. Rotate stand to desired position at bottom of heater (See Figure 2).
3. Tighten knobs.
4. Proceed to OPERATING INSTRUCTIONS.
Note: The heater must be operated with the stand attached to the heater
Wall Mount
1. Remove stand from heater by removing knobs and washers from both
sides.
2. Mount stand in desired position on wall (See Figure 3). The wall and
mounting hardware must be of adequate strength to support the heater.
Note: A 240 volt receptacle must be within six feet of the heater.
3. Install heater on stand and reassemble knobs, washers, stand and bracket
according to Figure 4.
4. Tighten knobs.
5. Proceed to OPERATING INSTRUCTIONS.

INSTALLATION INSTRUCTIONS

without stand
RCP402S - 20 Amp
Plug Configuration
Receptacle Configuration
NEMA #6-20R
Figure 1
5. Heater must be kept clear of all obstructions:
3 foot minimum clearance from front, 6 inch
minimum clearance from back and top, and 12
inch minimum clearance from sides. See Figure
3.
6. Always plug the heater directly into a 240 volt
wall receptacle. Never use an extension cord.
STAND
STEEL
WASHER
KNOB
Figure 2
Figure 3
BRACKET
RUBBER
WASHER
Figure 4