Dispenser Assembly Tests

1. Enter service mode.
2. Run Test 8.
3. Verify diverter moves to each position, see
diagram below.
Dispenser Assembly Diagnostics
See Diverter Motor Assembly Diagnostics.
Dispenser Assembly Removal
1. Disconnect power to unit.
2. Remove the dispenser drawer.
3. Remove the control panel. (See Control Panel
Removal)
4. Remove the top panel. (See Top Panel Removal)
5. Remove the four 1/4" dispenser body screws.
1/4" Hex
1/4" Hex
1/4" Hex
1/4" Hex
6. Bend the four vent tube embosses as shown
below.
7. Using a large fl at blade screwdriver, pry the vent
tube off the dispenser body.
8. Remove the diverter motor. (See Diverter Motor
Assembly Removal)
9. Slide the dispenser body toward the rear of the
washer approximately 1/2" then pull housing
toward the center of the washer.
10. Remove the hoses connected to the back of the
dispenser housing to remove.
Note: When reinstalling the dispenser housing,
ensure the water restricter and vent tube O-ring is
installed.